.. SPDX-License-Identifier: GPL-2.0-or-later Kernel driver e50sn12051 ======================== Supported chips: * Delta E50SN12051 Prefix: 'e50sn12051' Addresses scanned: - Datasheet: Provided by Delta upon request and NDA Description ----------- E50SN12051 is a 600W non-isolated 1/8th brick DC-DC power module. This driver supports the E50SN12051 PMBus compliant monitor device. The device provides measurements for: * Input voltage * Output current * Output voltage * Temperature The driver is based on the PMBus core and exposes standard hwmon sysfs attributes. Sysfs attributes ---------------- ======================= ======================================================= curr1_label "iout1" curr1_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register. curr1_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status. curr1_input Measured current. From READ_IOUT register. curr1_max Maximum current. From IOUT_OC_WARN_LIMIT register. curr1_max_alarm Current high alarm. From IOUT_OC_WARN_LIMIT status. in1_label "vin" in1_alarm Input voltage alarm. in1_input Measured voltage. From READ_VIN register. in2_label "vout1" in2_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register. in2_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status. in2_input Measured voltage. From READ_VOUT register. in2_max Maximum voltage. From VOUT_OV_WARN_LIMIT register. in2_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status. temp1_crit Critical high temperature. From OT_FAULT_LIMIT register. temp1_crit_alarm Module temperature critical high alarm. Set by comparing READ_TEMPERATURE_1 with OT_FAULT_LIMIT if TEMP_OT_FAULT status is set. temp1_input Measured module's hot spot temperature. From READ_TEMPERATURE_1 register. temp1_max Maximum temperature. From OT_WARN_LIMIT register. temp1_max_alarm Module temperature high alarm. Set by comparing READ_TEMPERATURE_1 with OT_WARN_LIMIT if TEMP_OT_WARNING status is set. ======================= =======================================================